Australian Owned for 100 years in 2016
freecall
1800 623 350
Australia wide
 

Delta UPS Product Families



Agilon Family

Under 1.5kVA or higher

PC and Peripherals


VX Series, Line-interactive, 600/1000/1500VA

    Reliability

  • The integrated AVR (Automatic Voltage Regulation) stabilizes the output voltage for better power quality.
  • Excellent microprocessor control enables accurate detection of power frequency for higher reliability.
  • Wide input voltage range allows the UPS to work in harsh electrical environments and reduces battery discharging time.
  • Batteries are automatically recharged even when the UPS is in off mode and the UPS can start without mains (Cold-Start).
  • UPS is able to restart automatically while utility power is recovering.
  • Surge protection defends your critical load against damage.

    Convenience

  • Supplied with IEC output power cable for convenient connection to your load.
  • Several standard IEC 320 output sockets simplify the connectivity to computer and IT peripherals.
  • Compact size saves more space for critical equipment.

    Manageability

  • Standard USB communication port enhances monitoring and manageability.
  • Touch screen LCD for a clear display of UPS information.
  • Advanced UPS management software provides remote shutdown and control.
VX Series 600/1000/1500 VA UPS (Quick Guide)

Amplon Family

1kVA or higher
Server and Network Equipment


GAIA Series 1/2/3 KVA

  • Double-conversion technology provides 24/7 full-time protection.
  • Built-in batteries for basic runtime demands.
  • Battery-start capability without utility power.
  • RS232 and USB connectivity with power management software.
  • Built-in data line surge protector for phone/fax/network.
  • Rack or tower configuration in 2U size cabinet.
  • Optional external battery pack for longer backup time.
  • SMART slot for remote management.
  • Programmable output saves energy for important loads.
  • Input voltage range meets the needs of most applications and avoids frequent transfers to battery mode to help prolong battery life.
  • High input power factor (pf > 0.97) saves installation cost.
  • Intelligent management prevents battery from overdischarge.
GAIA Series 1/2/3 kVA UPS (Leaflet) GAIA Series 120V, 1/2/3 kVA UPS (Leaflet) GAIA Series 1/2/3 kVA UPS (User Manual)

M Series 1/1.5/2/3 kVA

    Availability

  • Hot swappable battery pack for easy maintenance.
  • Automatic voltage regulator (AVR) delivers stable output voltage.
  • Wide input voltage range reduces battery discharge occurrence and extends battery life.
  • Battery starts when utility power is not present.
  • Self test for battery replacement warning.

    Flexibility

  • Rack or tower configuration in 2U size cabinet.
  • Optional external battery pack (applicable for 3kVA model) for extendable backup time.
  • Communication slot for various smart cards to support various applications.
  • Intelligent management software connectivity via RS232 or USB port.

    Total Cost of Ownership

  • High output power factor 0.9 provides more real power to critical loads.
  • High efficiency online mode can reach at minimum 97% and 96% for 1/1.5kVA and 2/3kVA respectively supporting operating cost savings.
  • Automatic fan-speed control function lowers noise and prolongs fan life under different operation modes with lower speed.
M Series 1/1.5/2/3 kVA UPS (Leaflet) M Series 1/1.5/2/3 kVA UPS (User Manual)

N Series 1/2/3 kVA

    Availability

  • True online double-conversion topology and zero transfer time to battery ensure high reliability.
  • Advanced DSP (Digital Signal Processor) controller for fast computation capability and a simplified control circuit for enhanced stability.
  • Wide input voltage range allows the UPS to work in harsh electrical environments.
  • Generator compatibility ensures continuous and reliable power.

    Green with Low TCO

  • High input power factor (> 0.99) and low input harmonic distortion (iTHD < 3%) save upstream investment.
  • Output power factor up to 0.9 presents a stronger load capacity.
  • AC-AC efficiency up to 93% and high efficiency of 91% at 50% load results in marked energy cost savings.
  • Compact design saves more space for critical equipment.

    Intelligent Management

  • Excellent local communications through LCD display.
  • Intelligent battery management maximizes battery performance and sustains battery life.
  • Mini slot and USB port enhance monitoring and manageability.
N Series 1/2/3 kVA UPS (Leaflet)

N Series 6/10 kVA

    The Most Compact Design and Best TCO

  • The smallest dimensions in its class saves significant space for more critical equipment.
  • A pioneer in unity power factor (kVA=kW) to maximize power availability.
  • The highest AC-AC efficiency up to 95% and efficiency of 98% in ECO mode for exceptional energy cost savings.
  • Automatic speed regulation function with multi-stage fan speed control maximizes system efficiency, significantly reduces audible noise, and prolongs the service life of the fans.

    High Availability

  • True online double-conversion topology and zero transfer time to battery ensure high reliability.
  • Parallel configuration for expansion and N+X redundancy up to 4 units.
  • Advanced DSP (Digital Signal Processor) controller for fast computation capabilities and a simplified control circuit for enhanced stability.
  • Generator compatibility ensures continuous and reliable power.

    Intelligent Management

  • Excellent local communications through user-friendly LCD display and LED indicators.
  • Intelligent battery management maximizes battery performance and extends battery life.
  • Various types of communication interfaces enhance monitoring and manageability.
N Series 6/10 kVA UPS (Leaflet) N Series 6/10 kVA UPS (User Manual) N Series 6/10 kVA UPS - Maintenance Bypass Box (Quick Guide)

R Series 1/2/3 kVA

    Availability

  • True online double-conversion topology provides zero transfer time to ensure maximum protection of the equipment
  • Watch-dog design of the DSP (Digital Signal Processor) increases reliability
  • Cold-start capability provides temporary battery power when the utility power is out
  • Operating temperature tolerance up to 50°C ensures critical loads’ continuity
  • The Maintenance Bypass Box offers load continuity during battery replacement or other upgrades

    Flexibility

  • Compact dimensions meet the needs of different rack cabinets
  • Convertible rack and tower configuration in 2U size cabinet
  • Excellent local communications through rotatable LCD display
  • Intelligent management software connectivity via RS232, mini slot or USB port

    Low Total Cost of Ownership

  • Wide input voltage range reduces the chance of using the battery and extends battery life
  • Intelligent battery management sustains battery life and performance
  • High output power factor of 0.9 provides more real power to critical loads
  • High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 3%) save upstream investment
  • Up to 93% AC-AC efficiency and 96% efficiency in ECO mode results in marked energy cost savings
  • Fan speed control by load level and room temperature optimizes performance
R Series 1/2/3 kVA UPS - External Battery Pack (Quick Guide) R/RT Series 1/2/3 kVA UPS - Maintenance Bypass Box (Quick Guide) UPS Amplon Family - Over Voltage Cutoff Device (Quick Guide)

RT Series 1/2/3 kVA (Face-Lift model)

    Availability

  • True online double-conversion topology and zero transfer time to battery ensure high reliability.
  • Watch-dog design of DSP (Digital Signal Processor) increases reliability.
  • Cold-start capability provides temporary battery power when the utility power is out.
  • Fan failure detection alerts users to failed fans.
  • Hot swappable batteries ensure continuous operation even when batteries are being replaced.
  • Optional external battery pack for easy scaling of longer backup time.
  • Operation temperature tolerance up to 50°C ensures critical loads' continuity

    Green & Low TCO

  • High output power factor 0.9 provides more real power to critical loads.
  • High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 5%) save upstream investment.
  • Up to 94% AC-AC efficiency and 97% efficiency in ECO mode result in marked energy cost savings.
  • Wide input voltage range reduces the chance of using the battery and extends battery life.
  • Intelligent battery management sustains battery life and performance.
  • Fan speed control by load level maximizes efficiency and reduces audible noise.

    Flexibility

  • Load segment control allows less-critical loads to be disconnected during blackouts and saves battery runtime for important loads.
  • Convertible rack and tower configuration in 2U size cabinet.
  • Excellent local communications through rotatable LCD display.
  • Intelligent management software connectivity via RS232 or USB port.
RT Series 1/2/3 kVA UPS (Leaflet) RT Series 1/2/3 kVA UPS (User Manual) RT Series 1/2/3 kVA UPS - External Battery Pack (Quick Guide) R/RT Series 1/2/3 kVA UPS - Maintenance Bypass Box (Quick Guide) UPS Amplon Family - Over Voltage Cutoff Device (Quick Guide)

RT Series 5/6/10 kVA

    Availability

  • True online double-conversion topology provides 24/7 fulltime protection.
  • 1+1 parallel redundancy or expansion without requiring additional hardware.
  • AC-start and battery-start capabilities.
  • Additional charger board can be added to reduce recharging time.
  • Optional maintenance bypass box for parallel redundancy with manual bypass switch.
  • External charger box enhances battery charging ability.

    Flexibility

  • Rack or tower configuration.
  • Multi-language LCD display with blue backlight.
  • Optional external battery pack for longer backup time.

    Low Total Cost Of Ownership

  • Output factor 0.9 delivers more real power.
  • High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 5%).
  • Common battery installation enables two UPS in parallel to share one battery source for cost savings.
  • Wide input voltage range reduces battery discharging occurrence and prolongs battery lifetime.
RT Series 5/6/10 kVA UPS (Leaflet) RT Series 5/6/10 kVA UPS (User Manual) Removal and Installation of Air Filter for RT Series (User Manual) External Battery Pack for RT 5/6/10kVA UPS (Quick Guide) Maintenance Bypass Box for Parallel UPSs Installation and Operation Guide Maintenance Bypass Box for Single UPS Installation and Operation Guide

Ultron Family

10kVA or higher
Datacenter and Industrial Equipment



EH Series 10/15/20 kVA

    Assured Reliability

  • True online double-conversion technology to completely isolate the output power from all input anomalies.
  • DSP based technology to support rapid computation capability and a simplified control circuit for enhanced stability.
  • Dual input design to allow different power supply sources for enhanced availability.
  • Built-in manual bypass to ensure continuous power to the load even if the UPS fails.

    Best Total Cost of Ownership

  • A wide input voltage range to reduce battery discharge probability and prolong battery life.
  • ECO mode efficiency up to 96% to reduce operating cost.
  • Small footprint to save space.

    High Flexibility

  • Parallel expansion and N+X redundancy up to 4 units without requiring additional hardware.
  • Additional charger and external charger box for flexible capacity expansion.
  • Remote and local emergency power-off functions (EPO) to promptly manage the UPS when emergencies occur.

    Easy Manageability

  • Multi-connectivity interface to support remote UPS monitoring and management.
  • Advanced management software to provide event alert management, remote shutdown event log tracking and analysis.
  • Reliable battery management for better battery protection.
EH Series 10/15/20 kVA UPS (Leaflet) EH Series 10/15/20 kVA UPS (User Manual)

HPH Series 20-120 kW

    Best-in-Class Power Performance and Efficiency

  • Fully rated power (kVA=kW) for maximum power availability
  • Leading AC-AC efficiency up to 96% saves energy costs
  • Low harmonic pollution (iTHD<3%) and high input power factor (>0.99) reduce upstream investment costs

    Assured Reliability

  • Wide input voltage range allows the UPS to operate in harsh electrical environments and extends battery life
  • DSP based technology enables reduction in the number of electronic components to lower failure rate
  • Redundant auxiliary power and fan design* enhance system reliability (* Applied for models HPH-60/80/100/120K)
  • Watch-dog design of dual auxiliary power circuit to eliminate single-point failure to ensure reliability
  • Built-in manual bypass ensures continuous power to the load even if the UPS is under maintenance

    Greater Flexibility

  • A wide choice of configurations, such as N+X redundancy and hot stand-by
  • Adjustable charging current and charging voltage meet different battery configuration requirements
  • Flexible battery configuration optimizes battery investment

    Superior Serviceability and Management

  • Front-door battery replacement with hot-swappable battery tray design supports easy and quick replacement without turning the unit off (HPH-B / BN)

    HPH-B: UPS integrated battery model has batteries inside

    HPH-BN: UPS integrated battery model has no batteries inside

  • Swappable interior architecture and front access servicing enables quick and easy maintenance* (* Applied for models HPH-60/80/100/120K)
  • Multi-connectivity interface supports remote UPS monitoring and management
HPH Series 20/30/40/60/80/100/120 kW UPS (Leaflet) HPH Series 20/30/40 kW UPS (User Manual) HPH Series 20/30/40 kW UPS - integrated battery model (User Manual) HPH Series 60/80/100/120 kW UPS (User Manual)

HPH Series 160/200 kVA

    Best-in-Class Power Performance and Efficiency

  • High AC-AC efficiency of up to 96.5% and ECO mode to 99% for significant energy cost savings
  • Low harmonic pollution (iTHD < 3%) and high input power factor (> 0.99) reduces upstream investment costs

    Assured Reliability

  • Optional redundant controller supports dual CAN bus and ring connection for high system availability
  • Proactive battery aging detection for high reliability
  • Easy event log check via touch panel and firmware upgrade via USB port

    Greater Flexibility

  • Parallel expansion and redundancy up to 8 units, 1.6MVA of total power capacity
  • Flexible battery configuration 30~46 pieces optimizes battery investment
  • Supports either top or bottom cable entry in the single cabinet. The unique fixed symmetric terminal design avoids cable bending issues to enhance cable reliability

    Superior Serviceability and Management

  • User-friendly 10” colored LCD with touch panel enables easy local UPS management
  • Environment information such as security, water, fire and temperature can be integrated into the UPS for easy monitoring via the LCD of the UPS
  • If the UPS is equiped with Delta's battery management system, the battery information can be integrated into the UPS and monitored via LCD
HPH Series 160/200 kVA UPS (Leaflet) HPH Series 160/200 kVA UPS (User Manual)

HPH Series 20-60 kW (208/120V)

    Best-in-Class Power Performance and Efficiency

  • Fully rated power (kVA=kW) for maximum power availability
  • Leading AC-AC efficiency up to 94% saves energy costs
  • Low harmonic pollution (iTHD<3%) and high input power factor (>0.99) reduce upstream investment costs

    Assured Reliability

  • Parallel expansion and N+X redundancy up to 4 units
  • Redundant auxiliary power and fan design enhance system reliability
  • Optional IPX1 level protection

    Greater Flexibility

  • A wide choice of configurations, such as N+X redundancy and hot stand-by
  • Adjustable charging current and charging voltage meet different battery configuration requirements
  • Flexible battery configuration optimizes battery investment

    Superior Serviceability and Management

  • Front-door battery replacement with hot-swappable battery tray design supports easy and quick replacement without turning the unit off
  • Swappable interior architecture and front access servicing enables quick and easy maintenance
  • Multi-connectivity interface supports remote UPS monitoring and management
HPH Series 20/30/40/60 kW UPS, 208/120V (Leaflet) HPH Series 20/30/40/60 kW UPS, 208V (User Manual)

NT Series 20-500 kVA

  • Available from 20 to 4,000 kVA (8 x 500 kVA in parallel).
  • Parallel redundancy without requiring extra hardware to increase reliability.
  • Optional harmonic filter and 12-pulse rectifier.
  • Redundant auxiliary power and control circuit ensures higher reliability.
  • Inbuilt maintenance and static bypass switch.
  • Multi-language LCD display and LED status indicators.
  • RS232, RS485 and six programmable dry contact outputs.
  • Compatible with generator installation and unbalanced loads.
  • Optional external battery cabinet for longer backup time.
  • Parallel expansion as your business grows and consequently saves initial investment.
  • Wide input voltage range extends battery lifetime.
  • Economy mode saves energy and operating cost.
  • Common battery installation saves initial investment.
NT Series 20-500 kVA UPS (Leaflet) NT Series 10-500 kVA UPS (User Manual)

DPS Series 160-500 kVA

    High Reliability

  • N+X redundancy or hot-standby configuration ensures increased system reliability
  • Wide input voltage ranges (DPS 160kVA~500kVA : -40% ~ +20%) allows the UPS to work at optimal performance levels even in harsh electrical environments
  • Field programmable sequential start-up reduces the impact on the generator
  • Intelligent fan speed control and redundant fan design prevent UPS from overheating and increase overall system reliability
  • Parallel link functionality improves the stability of the output load, keeping the output load stable and the flow of power uninterrupted in the event of failure by a single UPS

    Reduced Total Cost of Ownership

  • High AC-AC efficiency even at light load levels reduces energy loss and lowers ongoing operating costs
  • High input power factor (> 0.99) and low input harmonic distortion (iTHD < 3%) eliminate the need to oversize the genset, reducing initial capital investment

    Easy Maintenance

  • Hot-swappable fans reduce maintenance lead time (applicable for 160 kVA UPS through 500 kVA UPS models)
  • Built-in manual bypass allows zero downtime and ensures system availability even during service maintenance
  • Main I/P and O/P switches detection provide quick diagnosis when faults occur

    Intelligent Battery Management

    Delta’s intelligent battery management system can maximize and sustain the lifespan of batteries, and efficiently utilize the capacity of any backed-up battery due to the following functions:

  • Battery temperature monitoring & compensation
  • Battery remaining capacity displayed in percentage
  • Protection against overcharge and discharge
  • Boost/float stage charge
  • Auto or manual battery test
  • 38~42 battery units in one battery cabinet optimizes investment (applicable for 160kVA UPS through 500kVA UPS models)
DPS 160/200/300/400/500 kVA UPS (Leaflet) DPS 160/200 kVA UPS (User Manual) DPS 300/400/500 kVA UPS (User Manual)

Modulon Family

20kVA or higher
Modularization. Unit expansion and Redundantpower supply can be achieved within a single rack.


DPH Series 25-75/150/200 kW

    Ultimate Availability

  • Advanced fault-tolerant design achieved by self redundancy to guarantee operation continuity
  • Self-synchronization of power and control modules for continuous on-line operation even in the event of control module failure to avoid downtime caused by single point failure
  • Hot-swappable key modules and components to ensure Mean Time To Repair (MTTR) close to zero without downtime risk
  • Wide input voltage range of -45% to +25% and narrow output voltage regulation window to cope with harsh utility conditions and seamlessly provide stable power supply to the load
  • High overload protection to support 125% overload for 10 minutes and 150% for 1 minute

    High Scalability

  • Vertical expansion from 25kW to 75/150/200kW supporting N+X redundancy in a single rack enclosure to save footprint
  • Parallel expansion up to four units without requiring additional hardware
  • Variable configurations possible providing the scalable flexibility up to Tier 4 standard

    Excellent Power Performance and Efficiency

  • Fully rated power (kVA=kW) to maximize power availability
  • High AC-AC operating efficiency of 95% at 30% light load and 96% from 50% load resulting in marked energy cost savings
  • Low harmonic pollution (iTHD<3%) to reduce upstream investment costs and meet demanding power requirements

    Easy Maintenance

  • Built-in manual bypass features to eliminate maintenance-related downtime
  • Proactive detection of fan failure and switch fault for early diagnosis on UPS malfunction
  • Plug and play to simplify the maintenance process
DPH Series 25 - 75/150/200 kW UPS (Leaflet) DPH Series 25-200 kVA UPS (Brochure) DPH Series 25-75 kW UPS (User Manual) DPH Series 25-150 kW UPS (User Manual) DPH Series 25-200 kW UPS (User Manual)

DPH Series 50-300/500/600 kVA

    Excellent Power Performance

  • The industry's leading power density per module at 50kW in 3U space, and the smallest footprint for 500kVA in a single rack and 600kVA in two racks, to achieve the best utilization compared with its peers
  • High AC-AC efficiency up to 96.5% and ECO mode to 99% resulting in marked energy cost savings
  • Green mode featuring a load aggregation function optimizes system efficiency

    Ultimate Availability

  • Fully modularized design and hot-swappable key modules ensure Mean Time To Repair (MTTR) close to zero without downtime risk
  • Redundant components and dual CAN bus delivers highest system availability and avoids single point of failure
  • Modular UPS grows with your business by parallel expansion up to 8 units for 4.8MVA of total power capacity

    High Manageability

  • User-friendly 10” color touch screen enables easy local UPS management
  • Environment information such as security, water, fire, and temperature can be integrated into the UPS for easy monitoring via the LCD of the UPS
  • If the UPS is equipped with an external battery management system, the battery information can be integrated into the UPS and monitored via the LCD of the UPS
DPH Series 50 - 300/500/600 kVA UPS (Brochure) DPH Series 50 - 300/500/600 kVA UPS (Leaflet) DPH Series 200-500 kVA UPS (User Manual)

NH Plus Series 20-120 kVA

  • Available from 20 to 480 kVA (4 units x 120 kVA in parallel).
  • Redundancy at module and system level.
  • Hot-swappable function ensures uninterrupted operations during maintenance.
  • Redundant auxiliary power and control circuit ensures higher reliability.
  • Inbuilt maintenance and static bypass switch.
  • Modular design provides easy maintenance and scalability.
  • Multi-language LCD display and LED status indicators.
  • Two smart slots and six programmable dry contact outputs.
  • Optional external battery cabinet for longer backup time.
  • Low harmonic distortion (iTHD<3%) optimized generator size to save initial investment.
  • High input and output power factor (I/P pf >0.99; O/P pf up to 0.9) and 94% high efficiency reduce operating costs.
NH Plus Series 20-120 kVA UPS (Leaflet) NH Plus Series 20-120 kVA UPS (User Manual)
Copyright 2011 © Power Parameters Pty Ltd | Ph: 1800 623 350 | Fx: 1800 067 263 | power@parameters.com.au