We live up to our name, Power Parameters

Friday, December 15, 2017

Power parameters like voltage phase balance, harmonics and inter-harmonics, flicker, voltage swells, brownouts, etc. can critically affect electrical plant. Motors can draw 20% or more additional full load current due to voltage phase imbalance as little as 4%. Analyzing voltage as positive, negative and zero sequence and appropriate alarms when out of balance reaches a critical point can save significant dollars.

At Power Parameters, we have the instrumentation from the world leaders in power quality analysis AND the expertise to solve your power quality problems.

Camille Bauer intelligent power meters
4-quadrant, ideal for switchboard and motor control board applications

Camille Bauer power meters can operate together with protection relays to provide smart motor control





Camille Bauer SINEAX AM series, 4-quadrant, AM 1000, 2000 (both class 1) and 3000 (class 0.5S) for 3-wire, 4-wire, single and 3-phase balanced, unbalanced and open wye circuits

Three-phase parameters including imbalance, symmetrical components, harmonics to the 50th order, active power and power factor, fundamental power, and reactive power

Phasor display of voltage and current including symmetrical components.

Periodic, event, and disturbance recording (with pretrigger) based on half-cycle with internal data storage via Micro SD card

Ethernet (Modbus/TCP, web server, NTP), RS485 (Modbus/RTU), digital I/O and 20 mA analogue with linear and segmented linear outputs.

Universal power supply: 24 to 48 V DC, 100 V AC or DC to 230 V AC or DC


Camille Bauer A Plus power quality and energy monitoring and SCADA 4-quadrant, for 3-wire, 4-wire, single and 3-phase balanced, unbalanced and open wye circuits

Harmonics, unbalance, earth faults, reactive power compensation, energy efficiency, and load profiling according to the requirements of IEC60688.

Line/phase voltage and current, THD(V), TDD(I), load factor, symmetrical components for V and I, imbalance (zero/positive sequence), phase angles, power factor, reactive and distortion reactive power per phase, harmonics to the 50th order

Measured quantities can be aggregated in steps of 2 cycles to 1024 cycles and synchronised via NTP servers or synchronising pulse.

Software for archiving of configuration and data, resetting including threshold values, and logic function outputs.

Profibus DP, Modbus/RTU via RS485 and Ethernet

 

For further information, please contact :

 

Power Parameters Pty Ltd,
83 Northern Road,
Heidelberg West, VIC 3081
Freecall: 1 800 623 350 
Freefax: 1 800 067 263
power@parameters.com.au
www. parameters.com.au


Copyright 2011 © Power Parameters Pty Ltd | Ph: 1800 623 350 | Fx: 1800 067 263 | power@parameters.com.au
Further information may be found at suppliers website